Loading...

Technical info

Safety Fence Belgium

Magnetic safety barriers

Safety Fence Belgium is allowed to install without placing an additional signal indicator in front of or on the site. The safety barriers are used to ensure the safety of workers on the track. This way, the active track can continue to function without an overload of signal indicators, and workers can continue to work on the inactive track. Despite the different types of works, it is permitted for personnel or machinery to enter the inactive track.

However, a minimum distance of 1.5 meters is required between the outside of the Safety Fence and the edge of the outer rail of the active track. The Safety Fence is placed over the entire length of the work area. This is done to avoid access to the active track over the entire width of the yard.

The Safety Fence is always placed on the track that remains in service and not on the track that is being worked on. This indicates that the security measures are specifically aimed at protecting people on the inactive track.

Safety Fence Belgium

Equipment description

  • Adjustable in both length and height
  • Electrical insulation
  • Magnetic coupling piece
  • Lightweight: weight = 12 kg
  • Robust and high-quality
  • Weather resistant: stainless steel and aluminum material
  • Fast installation (+- 20 min for 33m protection)

Product setup

  • The product can be adjusted to different distances
  • The distance between the nearest rail and the security is at least 1.5 meters and 2 meters
  • The distance can be easily adjusted using the product's sliding system every 0.1 meters

Control and maintenance

Magnet maintenance: Remove dirty particles from the head that cause reduced adhesion. If necessary, wipe the magnet with a brush.

Visual inspection: During installation, the components must be checked for defects when the system is installed along the track for a longer period of time.

Inspection: After any sudden event (shock, collision, ...) the material must be checked to see if it is still capable of functioning.

Periodic inspection: The system must be checked at least once a year by a CLI representative. Results are kept for at least 3 years.

Safety Fence Belgium